WARNING
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This pool pump must be installed by a licensed or certified electrician or a qualified pool installer in
accordance with the 2008 National Electrical Code (“NEC”) to current and/or all applicable local codes and
ordinances. The specific section of NEC covering your pump may vary depending on your location. Some
states, and/or municipalities may not have adopted the current NEC code. In this case your state or local
code may only be applicable and/or an earlier edition of the NEC may apply. Please check your local and
state codes and regulations before commencing any installation of this pump. Improper installation could
create, among other things, an electrical hazard which may result in death or serious injury to pool users,
installers, or others due to electrical shock, and/or property damage. Always disconnect power to the pool
pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury
to pool users, installers or others (due to electrical shock) and/or property damage.
SEA FLOW
®
Pump Owner's Manual
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Before installing this product, read and follow all warning notices and instructions accompanying this pump. Failure to
follow safety warnings and instructions can result in severe injury, death, or property damage.
WARNING
Attention Installer.
This manual contains important information about the installation, operation and safe use of this product.
This information should be given to the owner/operator of this equipment.
Important Notice
Table of Contents
IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS............................................................................ I-II
SECTION I. GENERAL INFORMATION .............................................................................................................. 1
SECTION II. MAINTENANCE .............................................................................................................................. 2
SECTION III. SERVICE ........................................................................................................................................ 3
SECTION IV. RESTART INSTRUCTIONS ............................................................................................................. 6
SECTION V. TROUBLESHOOTING ..................................................................................................................... 6
SECTION VI. TECHNICAL DATA .......................................................................................................................... 7
A. REPLACEMENT PARTS ............................................................................................................................ 7
B. PUMP CURVES .......................................................................................................................................... 8
P/N 350522 Rev. E 7/12
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - SAVE THESE INSTRUCTIONS

WARNINGRISK OF ELECTRICAL SHOCK OR ELECTROCUTIONThis pool pump must be installed by a licensed or certified electrician or a qualified pool installer

Strany 2 - IMPORTANT NOTICE

SECTION VI. TECHNICAL DATAA. Replacement parts.ITEM 28 — IMPELLER CHARTNot Shown79129900 2-Speed Toggle Switch350202Seal Plate Kit: Seal plate (alm

Strany 3

B. Pump Curves.SAVE THESE INSTRUCTIONSSingle Speed ModelsDual Speed Models262827SEA FLOW®SEA FLOW®8

Strany 4

Warranty Policy• Warranty period starts from date of purchase and must be validated with copy of original purchase receipt.• Warranty requests b

Strany 5 - Clamp, pot

When installing and using this electrical equipment, basic safety precautions should always be followed, include the following:Do not permit children

Strany 6 - Figure 3

iiIMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS For Installation of Electrical Controls at Equipment

Strany 7

WARNINGTo reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.CAUTIONThis pump is fo

Strany 8 - Figure 4

NOTEWhen pump is mounted permanently within 5 ft. of the inside walls of a swimmingpool, you must use a No. 8 AWG or larger conductor to connect to bo

Strany 9

4. Put the debris from the basket into the trash and rinse out the basket. If the basket is cracked, it should be replaced.5. Replace the basket and f

Strany 10 - A. Replacement parts

d. If a motor has become wet - let it dry before operating. Do not allow the pump to operate if it has beenflooded.e. If a motor has been damaged by w

Strany 11

f. Hold the impeller securely in place and remove the impeller lock screw by using a #2 Phillips screwdriver.The screw is a left-handed thread and loo

Strany 12 - *350522*

CAUTIONThe polished and lapped faces of the seal could be damaged if not handled with care.CAUTIONIn mild climate area, when temporary freezing condit